OVERFLOW PIPE REAR ENTRY 
 
In your fitting kit you will find a straight push on connector with a small length of 
15mm copper tube pushed into it. 
 
If rear entry has been chosen this connector must be replaced by a push on 
elbow (available from plumber’s merchants). Push the elbow onto the overflow 
pipe on the bracket (alongside the solenoid). 
 
The pipe must have a continuous fall and should not be longer than 200mm (if a 
longer run is required use 22mm pipe to avoid airlocks). The overflow pipe 
should have no more than four right angle bends and should discharge to a safe 
visible position. 
 
Under certain conditions, the overflow pipe could vent steam, hot water or cold 
water and the manufacturers cannot be held responsible should damage arise 
from such discharge if the overflow pipe has not been directed to a suitable 
position where overflowing water can run away safely. 
 
Under no circumstances should the overflow pipe be allowed to vent 
inside the case of the boiler. 
 
 
 
VENT PIPE 
 
A small silicone tube connects the boiler to the wall bracket. Ensure that this is 
connected and that the opening in the bracket is not obstructed. 
 
FIT CASE
 
 
Attach the L.E.D display lead to the case per the instructions. Using the fixing 
screws fit the outer case to the boiler.  
 
WB5E ONLY. FIT TAP 
 
 
Remove plastic plug from the tap boss. Ensure that the yellow washer is in 
place and carefully screw the chromed tap extension into place using a 28mm 
open-ended spanner to tighten. Do not use grips or tools that are likely to 
scratch the chrome. 
 
Push the grey tap collar firmly into place and twist to fit snugly against the case.