Polycom 3725-70003-009F 사용자 설명서

다운로드
페이지 300
Configuring the ReadiVoice System
Proprietary & Confidential 
123
  
Changing the Talker Update Frequency 
Through the Operator and Moderator interfaces (and the APIs), the 
ReadiVoice system can report which two channels in a conference have talk 
slots. By default, talker information is updated every two seconds, but this 
interval can be lengthened to reduce the load on the system. 
To change the talk slot update interval for the system: 
1
Open a Telnet session to the CACS and log in as cnow (or log directly into 
the CACS as root and switch user to cnow). 
2
Open the.odprocrc file for editing, and find the [bridgeInt] section. 
The updateIntervalFrequency keyword sets the talker update 
frequency. By default, it’s set as follows: 
3
To reduce the update frequency (lengthen the interval), change the value 
to an integer greater than 2. Then, save the.odprocrc file. 
4
As root, stop and restart the ReadiVoice system as described in 
Caution! 
Perform the following procedure after operational hours. Don’t reduce the interval to 
less than two seconds. 
[bridgeInt]
... 
updateIntervalFrequency = 2