Power Requirements
The CineWall requires clean, noise-free AC power. The power cord provided with the 
CineWall is 6 feet (1.83 meters) long. In order to use it, the power outlet must be no more 
than 48 inches (1.22 meters) from the cable openings on the right side of the chassis. If 
the outlet is farther away, substitute a longer power cord for the one provided with the 
CineWall; do not use a power strip or extension cord. If you use a substitute power cord, 
ensure that it is a UL- or CSA-approved, three-conductor (18 AWG or heavier), shielded 
cord rated at 10 amps minimum.
Site Access
The CineWall is shipped in two containers: one for the screen assembly and one for the 
chassis and related hardware. The shipping container dimensions are as shown below. 
Ensure that the site has a “carry-in” path with sufficient clearances leading to the 
installation location. This is particularly important in corners in stairways, landings and 
hallways. 
101.13 
in. (2,568 mm)
7.5 in.
(190 mm)
61.5 in.
(1,562 mm)
Chassis/Hardware
Screen
86.25 in. (2,191 mm)
30.0 in.
(762 mm)
58.5 in.
(1,486 mm)
A
A 2,000 
mm
B 4,000 
mm
C 1,900 
mm
D 1,200 
mm
E 2,400 
mm
F 3,700 
mm
B
C
D
E
D
F
A
Minimum Stair/Landing Clearances