Runco CW-95DHD 사용자 설명서

다운로드
페이지 106
62
CineWall™ Installer/Integrator Manual
PRE
L
IMINAR
Y
Figure 5-6. Overscan Modes
Phase (RGB or Component sources): This control adjusts the phase of the pixel 
sampling clock relative to the incoming signal. Adjust the phase when an RGB or 
Component image still shows shimmer or “noise” after Tracking has been optimized. 
For best results, use a good test pattern such as a smooth gray consisting of a clear 
pattern of black and white pixels, or a similar “half on, half off” graphic image. Adjust the 
slidebar until the image stabilizes and each pixel is clearly defined. You may notice that 
you can stabilize the image at more than one point. Use either setting in such cases. 
Tracking (RGB or Component sources): Tracking determines the frequency of the 
pixel sampling clock, indicated by the number of incoming pixels per line, so that all pixels 
generated by a particular source are sampled. 
Steady flickering or several soft vertical stripes or bands across the entire image indicates 
poor pixel tracking. Proper pixel tracking helps ensure that the image quality is consistent 
across the screen, that aspect ratio is maintained and that pixel phase (see above) can be 
optimized. 
Adjust the Phase after adjusting Tracking (see below). 
No Overscan
Crop
Zoom
4:3
16 :9
= Source Image Area
= Mask (Crop) Area
= Screen (16:9)
Tip