Centrifugal Pump Operator's Manual 
 
                  
             11  
Trouble Shooting 
SYMPTOM 
PROBLEM 
SOLUTION
Cannot pull or hard 
to pull recoil starter 
Debris caught in impeller 
Dismantle & clean impeller
Not enough delivery 
volume 
Air leakage on suction 
Check suction hose and 
   
 
side 
suction connections
   
 
Engine not performing 
Check & repair engine 
   
 
 
see John Deere dealer
   
 
Damage to mechanical 
Replace mechanical seal 
   
 
seal 
see John Deere dealer
   
 
Suction lift is too high 
Make suction lift lower
   
 
Suction hose is too long 
Shorten suction hose or 
   
 
or smaller in diameter 
enlarge diameter
   
 
Leakage of water from  
Stop leakage of water 
   
 
discharge hose
   
 
Worn out impeller 
Replace the impeller  
   
 
 
see John Deere dealer
Pump does not 
Air goes in from suction 
Check hose and suction 
prime  
side 
connections (See Solution 2)
   
 
Insufficient priming water 
Pour more water into 
   
 
inside pump  
pump casing for priming 
   
 
 
   
 
Drain plug is loose 
Tighten drain plug firmly.
   
 
Damage of mechanical seal 
Replace mechanical seal 
   
 
 
see John Deere dealer
   
 
Wrong suction hose used 
Use correct suction hose
   
 
Water leakage between engine   Damaged mechanical 
   
 
and pump  
seal. Replace see John  
   
 
 
Deere dealer.
Engine does not 
 
Refer to engine manual 
start  
 
see John Deere dealer