PUMP RECOMMENDATION FOR
COPPER-FIN II 0991-1441 POOL HEATER
Pump Specifications
Part No.
HorsePower
Flanges
Valute Material
Flange Material
Vendor
Vendor Product Series
Orientation
ARM3024PABTE 1/2 2-1/2" Brass
Brass Armstrong
2B1050
Vertical
Installation Specifications
Recommended for
Based on
Pump
Model Numbers
Maximum GPM
Installation Type
Copper-Fin II Pool Htr, CP(N,L) 0991-1441
90 GPM
Single Pool Heater piped Primary/Secondary to Pool Loop
ARM3024PABTE
Based on
Based on
Minimum Pipe Diameter
Connecting piping
2-1/2"
Maximum 45 feet straight pipe with 6-Elbows, 2-Unions and 2-Ball Valves
IMPORTANT: Read the Copper-fin II 500-2070 Pool Installation and Operation Manual. If the planned
system exceeds the pump capacity in flow and/or head see “Pump Curves-All Pumps” for alternate pumps
and pump curves.
system exceeds the pump capacity in flow and/or head see “Pump Curves-All Pumps” for alternate pumps
and pump curves.
PUMP
Recommendation
PUMP-Rec-08 Rev C
OIL PORT
A
C
B
D
11-1/2”
19-1/2”