– 15 –
5. The display changes a shown below each time the jog key on
the set is turned up or 
[DISPLAY]
 key on the remote com-
mander is pressed.
However in the power mode (mode number 700’s), only the
power adjustment value is displayed.
6. Quit the manual mode, and press
x
key to return to the test
mode (display check mode).
A D     8 5
731
• Power Supply Adjusted Value
LCD display
mode number
fixed display
adjusted value
4-4. OVERALL ADJUSTMENT MODE
Mode to adjust the servo automatically in all items.
Normally, automatic adjustment is executed in this mode at the
repair.
Adjust the CD first, when performing adjustment.
• Configuration of overall adjustment
For further information, refer to the Section 5 Electrical Adjust-
ment. (See page 20)
• Address & Adjusted Value Display
LCD display
• Jitter Value & Adjusted Value Display
LCD display
• Block Error Value & Adjusted Value Display
LCD display
• ADIP Error Value & Adjusted Value Display
LCD display
• Item Title Display
LCD display
C 6 8 S 0 1
011
0 6 3 B 0 1
011
0 5 9 A 0 1
011
L r e f P w   0 1
011
0 F F J 0 1
011
mode number
address
adjusted value
mode number
jitter value
adjusted value
mode number
block error value
adjusted value
mode number
ADIP error value
adjusted value
adjusted value
mode number
item title
 
 key
 
 key
 
 key
Title
display
CD overall
adjusting
CD overall
adjustment
OK
MO overall
adjusting
MO overall
adjustment
OK
CD overall
adjustment
NG
MO overall
adjustment
NG
 
 key
protect switch ON
All item 
OK
protect switch OFF
NG item exists
or  
 key
NG item exists
or  
 key
 
 key
 
 key
 
 key
 
 key
[Test mode $display check mode%]