Known Problems
39
In addition, the port for which the report is requested does not have 
to be involved in the trunk for this situation to occur.
On a CoreBuilder 9000 with a single switch fabric module installed, 
when you insert a switching module that supports trunks on the 
backplane into an unpopulated slot that has AutoMap enabled, only 
the first link of the trunk for that slot is in the Up state, and other links 
are in the Down state.
There are two ways to avoid this problem:
Do not enable AutoMap on an unpopulated slot. Enable AutoMap 
after you insert the switching module.
Enable all backplane links in that slot that are in the Down state. 
(30041)
In a redundant switch fabric module configuration, when AutoMap is 
enabled for an unpopulated switching module slot, the backplane 
trunk does not enter the Up state.
There are two ways to avoid this problem:
Populate the switching module slot before you enable AutoMap.
Always allow 90 seconds for the secondary switch fabric module to 
be updated before you reset the primary switch fabric module.
Remove the secondary switch fabric module before you enable 
AutoMap, then reinsert the secondary module, and reset the 
primary switch fabric module so that the AutoMap change takes 
effect and backplane trunks are created. (30051)