Everpure ENVI-RO 사용자 설명서

다운로드
페이지 16
20.0 508
5.0 127
3.1 80
16X .33
 THRU
8.4
17.8 452
16.6 422
15.4 391
14.2 361
4.2 107
Low TDS 
Outlet 
(Steamer)
Inlet 
(From Filter System)
Reduced TDS 
Outlet 
(Coffee)
ENVI-RO 
System
2SR-BW 
Conditioning 
Cartridge
MR-600 
RO Cartridge
RO Reject 
(3/8" John 
Guest) route 
to drain
figure 1. Wall mount bracket.
figure 2. ENVI-RO Assembly.
2
noteS: 
Please read this manual prior to installing and operating the 
system. 
Incoming water supplies that do not meet these requirements 
may need additional pre-treatment prior to the system. System 
performance may be affected if requirements are not met, 
including system output production and cartridge change-out 
frequency. 
Consult with your local building inspector for approval and 
required permits to install this system. Additional equipment, such 
as back-flow prevention devices, seismic restraint equipment, air 
gaps, etc., may be required. Completed installation must meet all 
local and national codes.
Do not connect the ENVI-RO™ system after any water filtration 
system, unless specifically provided or specified for use with the 
ENVI-RO™ system. 
unPackIng and InSPectIon
The ENVI-RO™ includes all the necessary fittings for installation. 
Lengths of 3/8" tubing have been provided for connecting to the 
wastewater/drain connection. Supply lines and distribution piping/
tubing are not included. 
The ENVI-RO™ system is packaged as a complete unit in one carton. 
At a minimum, you should have the following:
Plate mounted processor assembly including:
1. 
Dual-head Pump 
Cartridge Heads 
Controller & Power Supply
Storage Tank 

Wall Mount Bracket
2. 
MR-600 RO cartridge 
3. 
2SR-BW Cartridge
4. 
Parts Kit
5. 
Inspect the carton for damage. Report any damage to freight carrier 
immediately and retain all packaging materials. Carefully unpack and 
inspect each item. 
SyStem aSSembly
Locate the system in an area that is convenient to the inlet water 
supply and drain facilities, with access for routing the product water 
tubing/piping to the equipment. Install in a dry location, away from 
all forms of corrosive and/or flammable materials. Consider ease 
of access for servicing when selecting a location. Evaluate the 
mounting surface for its ability to properly support the weight of the 
processor when in operation (Approximately 90 pounds).
WARNING
  Do not use screws smaller than #12 for mounting the 
processor.
WARNING
  Mounting surface may require reinforcement to 
support processor safely. Hollow walls, drywall and 
other non-structural surfaces are not suitable unless 
reinforced.
Processor assembly mounting
The ENVI-RO system has been provided with a wall mount 
1. 
bracket to allow greater installation flexibility and ease of 
processor placement. If the wall mount bracket is not suitable for 
this specific application, the processor backplate has 4 mounting 
holes (2 keyhole slots, 2 standard) on 16" centers for securing it 
directly to a vertical surface. 
Refer to 
2. 
figure 7 (page 13) for dimensional information. Use 
this as your guide to determine the wall mount bracket and/or 
processor location. If NOT installing the wall mount bracket go 
to step 5. 
continued on the next page  . . . 
Floor Drain
Maintain air-gap per local and national codes
Position top line of mounting holes 1-9/16” above 
the top edge of backplate