Russound CAM6.6T 사용자 설명서

다운로드
페이지 116
58
INSTALLER
INSTALLATION MENU
ZONE SETUP (ZonSu) 
NOTE: This procedure should be performed using the keypad installed in the zone to be configured.
See Zone Setup - Flow Chart on page 71
Zone Setup allows the installer to adjust properties of the UNO Keypad controlled CAM6.6 zone. This
series of menus allows the system’s zones to be configured for these properties:
ZON VOL TRIM (ZonVT) 
SYSON ENABLE (SysOn) 
PARTY ENABLE (PtyEn) 
MASTER ENABL (MstEn) 
MUTE ENABLE (MutEn)
1. ZON VOL TRIM 
This feature allows the installer to adjust the output volume to 
(ZonVT)
each zone. -16dB (lowest) to 0dB (max)(-3DB default). 
2. SYSON ENABLE
This feature is either disabled or enabled. If disabled (default), an
(SysOn) 
All On command activated from another zone will not turn on the 
disabled zone. If enabled, an All On command activated from 
another zone will turn on the enabled zone. 
3. PARTY ENABLE
This feature is either disabled or enabled. If disabled, Party Mode
(PtyEn) 
activation from another zone will not affect the disabled zone. If 
enabled (default), the zone will participate with Party Mode. 
4. MASTER ENABLE
This feature is either disabled or enabled. If disabled, the zone 
(MstEn)
cannot host a master keypad during Party Mode. If enabled 
(default), the zone has the option of hosting the Master keypad.
5. MUTE ENABLE
This feature is either disabled or enabled. It allows the option of 
(MutEn)
enabling or disabling muting in a zone. If disabled, the zone will 
not mute. If enabled (default), the zone will be muted when a 
mute signal is received. 
CTRLR SETUP (CtlId)
Controller Setup is the basic configuration of the controller. This setup menu selects the options for
Controller ID and Factory Initialization. 
See Controller Setup - Flow Chart on page 72
1. CONTROLLER ID  
This defines the Controller ID for this system. The default is 1 but
(CtlId) 
when multiple controllers are used, each additional controller ID 
must be sequential and unique and be set before being connect-
ed to the system. Note that the system must be restarted before
the controller will assume the new ID. 