Sony STR-DH550 사용자 설명서

다운로드
페이지 246
MULTI CHANNEL AV RECEIVER
STR-DH750/STR-DH550
List of messages after Auto Calibration measurements
Error 30
Headphones are connected to the PHONES jack on the receiver. Remove the headphones and perform the
Auto Calibration again.
Error 31
Front speakers are not selected properly. Select the front speakers using SPEAKERS and perform the Auto
Calibration again. For details on selecting the front speakers, see “
Error 32, Error 33
:
Speakers were not detected or not connected properly.
None of the front speakers are connected or only one front speaker is connected.
Either the surround left or surround right speaker is not connected.
A surround back speaker is connected only to the SPEAKERS SURROUND BACK/BI-AMP/FRONT HIGH/FRONT
B R terminal. If connecting only one surround back speaker, connect it to the SPEAKERS SURROUND BACK/BI-
AMP/FRONT HIGH/FRONT B L terminal (for STR-DH750 only).
Either the front high left or front high right speaker is not connected.
The optimizer microphone is not connected. Make sure that the optimizer microphone is connected properly
and perform the Auto Calibration again.
If the optimizer microphone is connected properly but the error code still appears, the optimizer microphone
cable may be damaged.
Warning 40
The measurement process has been completed and a high noise level has been detected. You may be able
to achieve better results if you try the process again in a quiet environment.
Warning 41, Warning 42
The input from the microphone is too large.
The distance between the speaker and the microphone may be too small. Set them further apart and perform the
measurement again.
Warning 43
The distance and position of a subwoofer cannot be detected. This may be caused by noise. Try performing
the measurement in a quiet environment.
4-488-933-11(1)
Copyright 2014 Sony Corporation
159