Phono Input Selector Switch 
q
The Phono input is for a moving magnet (MM) 
or moving coil (MC) phono cartridge only and 
is incompatible with line level components. Set 
the Phono Input Selector Switch as appropri-
ate for the phono cartridge you are using. 
Leave the switch button in the out position for 
a moving magnet cartridge; push the switch 
in for a moving coil cartridge. 
Some high output moving coil cartridges are 
designed to operate in the moving magnet 
position. If you are in doubt about the correct 
setting, check the instruction manual for your 
phono cartridge for information regarding its 
output voltage and the expected input imped-
ance. The Phono input has 47 kOhms input 
impedance and 2.5 mV sensitivity in the MM 
position and 100 Ohms input impedance and 
0.25 mV sensitivity in the MC position. If you 
still have questions about the proper setting of 
the phono input selector switch, consult your 
authorized Rotel dealer.
Phono Input 
e
 and  
Ground 
w
 Connection 
Plug the cable from the turntable into the ap-
propriate left and right phono inputs. If the 
turntable has a “ground” wire connect it to the 
screw terminal to the left of the Phono inputs. 
It will help prevent hum and noise.   
Recorder Connections 
t
The Tape 1 and Tape 2 inputs and outputs can 
be connected to any record/playback device 
that accepts standard line level analog input 
and output signals. Typically that will be a 
conventional tape recorder. 
When connecting a recorder to the RC-1082, 
remember that the outputs of the recorder must 
be connected to the tape inputs of the RC-1082. 
Similarly the tape outputs of the RC-1082 must 
be connected to the inputs of the recorder. As 
with other sources be sure to connect the Left 
and Right channels of each device to the proper 
channels on the associated components. Use 
high quality connecting cables to prevent loss 
of sound quality.
Output Connections 
u
Most RCA-type output connectors are compat-
ible with most power amplifiers. As always, use 
high quality cables and be sure to connect the 
Left and Right channel outputs of the RC-1082 
to the correct channels of the amplifier.
NOTE: There are two sets of RCA outputs 
on the RC-1082. The second set of outputs 
may be used in custom system configura-
tions to drive a second power amplifier or 
to supply a signal to a special signal pro-
cessor. 
12 Volt Trigger Outlet 
p
 
Some audio components can be turned on 
automatically when they receive a 12V turn on 
“signal”. The 12V Trigger Outputs of RC-1082 
provides the required signal. Connect the 
compatible components to the RC-1082 with a 
conventional 1/8” miniplug cable. When the 
RC-1082 is in Standby mode, the trigger signal 
is interrupted, so the components controlled 
by it are turned off.
IR Inputs and Outputs
External Remote Input 
i
 
This 3.5 mm mini-jack (labeled EXT REM IN) 
receives command codes from an industry-
standard infrared receivers (Xantech, etc.) 
located in the main listening room. This feature 
is useful when the unit is installed in a cabinet 
and the front-panel sensor is blocked. Consult 
your authorized Rotel dealer for information 
on external receivers and the proper wiring of 
a jack to fit the mini-jack receptacle.
NOTE: The IR signals from the EXTERNAL 
REMOTE IN jack can be relayed to source 
components using external IR emitters or 
hard wired connections from the IR OUT 
jacks.
IR Output 
o
The IR OUT 1 and 2 jacks send IR signals 
received at the EXTERNAL REM IN jack to an 
infrared emitter placed in front of a source 
component or to other Rotel components with 
compatible rear panel IR input connectors. 
This output is used to allow IR signals to pass 
along IR signals from a remote control when 
the sensors on the source components are 
blocked by installation in a cabinet.
See your authorized Rotel dealer for informa-
tion on IR repeater systems.
NOTE: The EXT REM IN jack located next 
to these jacks is for use with an external IR 
sensor duplicating the front panel IR sensor 
and located in the primary zone.
12V Trigger Connections 
p
Many Rotel amplifiers offer the option of turn-
ing them on and off using a 12 volt trigger 
signal sent to them. The RC-1082 provides two 
12 volt trigger outputs. When the RC-1082 is 
turned on, a 12 volt DC signal is sent to the 
amplifiers to turn them on. When the RC-1082 
is put in STANDBY mode, the trigger signal is 
interrupted and the amplifiers turn off.
To use the remote turn on feature, connect one 
of the RC-1082 12V TRIGGER OUT jacks to 
the 12 volt trigger input of a Rotel amplifier, 
using a cable with mono 3.5 mm mini-plugs 
on both ends. The +12 V DC signal appears 
at the “tip” connector.
NOTE: The number “1” 12V trigger signal 
is turned off when headphones are plugged 
into the front panel headphone outlet. See 
the Phones Output section.
Computer I/O Connector 
y
The RC-1082 can be operated from a personal 
computer running audio system control software 
from third-party developers. This control is 
accomplished by sending the operating codes 
normally sent by the RR-AT97 remote control 
over a hard-wired network connection from 
the computer.
The COMPUTER I/O input provides the neces-
sary connection on the back panel. It accepts 
standard RJ-45 8-pin modular plugs, such 
as those commonly used in 10-BaseT UTP 
Ethernet cabling.
For additional information on the connections, 
software, and operating codes for computer 
control of the RC-1082, contact your authorized 