7. POWER OFF CMD – 
Tells the controller to turn off the selected source equipment (by
(OfCmd)
SOURCE NUMBER) when the last of the UNO System Keypads is 
turned off. If “no,” procedure advances to SAVE CHANGES (step 11)
8. COMMAND TYPE – 
Select the type of source command (e.g., CD, TV, etc.). 
(CmdTp)
a. Selected: Learned IR
Choose Learned IR if the pre-programmed IR code library does 
(LrnIR)
not support the source component.
i. LEARNED SRC – 
Select the learned source bank to be assigned to the source 
(LnSrc)
component. Procedure advances to KEY FUNCTION (step 10)
b. Selected: Unassigned
The Power Off command is cleared. Procedure advances to 
(Unasg)
SAVE CHANGES (step 11)
c. Selected: Default
Default selects the same device type and device code previously
(Deflt)
setup in BASIC SETUP. Procedure advances to KEY FUNCTION 
(step 10)
d. Selected: Macro:
(To build macros, see Macro Editor page 60)
i. MACRO – 
Macro loads a series of commands which are processed when 
(Macro)
activated. 
ii. MACRO ID – 
Enter the macro ID number.Menu advances to SAVE CHANGES 
(MacID)
(step 11) 
e. All Other Selections:
Procedure advances to DEVICE CODE (step 9)
9. DEVICE CODE – 
Source component code for IR control.
(DevCd)
10. KEY FUNCTION – 
Select Keypad function.
(KyFn)
11. SAVE CHANGES? – 
Select “yes” to save the changes.
(Save?)
LEARN IR (LrnIR) 
This procedure allows IR commands to be learned into the system and be centrally stored in the main
controller to let the system access the same IR codes that operate the source equipment.
NOTE: IR codes must be learned in pointing the source’s remote control at the CAV6.6’s front panel
IR receiver. Use a keypad connected to the CAV6.6’s front panel programming port for convenience
in navigating the Learn IR procedure menu. 
See Installation Menu on Page 50 and Learn IR -
Flow Chart on page 70
INSTALLER
INSTALLATION MENU
Power Management (cont’d)