Packing List 
 
 
Examine the shipping carton and the contents for physical 
damage.  The following items should be in the shipping carton: 
1.   FBDA module 
2.   This instruction manual 
If any of these items are damaged or missing, contact B&B 
Electronics immediately. 
Software 
 
 
Software is not included with the FBDA module.  This device is 
used in conjunction with a data acquisition device.  All of B&B 
Electronics’ data acquisition modules come complete with software 
that you can modify to meet your exact needs. 
 
Calibration 
 
The FBDA is calibrated at the factory.  The excitation 
voltage is set to 5VDC ± 0.05VDC and the gain is calibrated at 80 ± 
2. The process of calibrating the FBDA and your sensor will vary 
depending on the type of sensor being used.  An example calibration 
procedure is covered in Chapter 3. 
 
FBDA Specifications 
 
Size: 
          4.8 
2.2 
0.9 
in
 
Maximum Input Voltage from Sensor:  440mV (using Gain = 25) 
Output 
Voltage 
Range:     0.003V 
to 
11VDC 
Gain: 
          25, 
40, 
80, 
220-1000 
Maximum Gain Error:   
 
 
 
 
5% of gain setting max. 
Input 
Offset 
Voltage:      150
µ
V max. 
Input 
Offset 
Voltage 
Drift: 
    1.5
µ
V/
o
Excitation 
Voltage: 
      0.5VDC 
to 
+11VDC 
Operating Temperature Range:   
 
0 to 70
o
Power 
Requirements: 
     13-18VDC 
@10mA 
(does 
 
not include current draw  
from excitation voltage.)