Mitsubishi Electronics MR-J2S- CL 사용자 설명서
3 - 21
3. SIGNALS AND WIRING
(b) Lamp load
For use of internal power supply
For use of external power supply
24VDC
VDD
COM
R
Servo amplifier
ALM, etc.
SG
COM
SG
R
24VDC
10%
10%
Servo amplifier
ALM, etc.
VDD
24VDC
Do not connect
VDD-COM.
VDD-COM.
(3) Encoder pulse output DO-2
(a) Open collector system
Interface
Servo amplifier
OP
5 to 24VDC
Photocoupler
SD
Max. output current : 35mA
LG
Servo amplifier
OP
SD
LG
(b) Differential line driver system
1) Interface
Max. output current: 35mA
LA
(LB, LZ)
(LB, LZ)
LAR
(LBR, LZR)
(LBR, LZR)
LG
SD
LA
(LB, LZ)
(LB, LZ)
LAR
(LBR, LZR)
(LBR, LZR)
SD
Servo amplifier
Servo amplifier
Am26LS32 or equivalent
High-speed photocoupler
150
100
2) Output pulse
Servo motor CCW rotation
LA
LAR
LB
LBR
LZ
LZR
T
/2
400 s or more
OP
LZ signal varies 3/8T on its leading edge.