2.1 Features 
 
The EM316EDFA board can run in standalone mode without any input from a management 
module. The EM316EDFA analog input power determines the output power because the module 
runs at a fixed gain. 
 
EM316EDFA status is reported through SNMP through a network management module as well as 
by LEDs on the front panel. 
 
The green “SD” LED on the front panel indicates input greater than the thresholds corresponding to 
the EDFA module type, as indicated in the table below. 
 
EM316EDFA-BR -8 
dBm 
EM316EDFA-LPR -30 
dBm 
 
A green LED at front panel (Optical Output) indicates output power greater than -10 dBm. 
 
The module temperature is measured from 0
 o 
C to 70
C and reported to management. To protect 
against excessive heat, the laser shuts down when measured temperature reaches 70
C. 
 
 
 
2.1.1 EM316EDFA-BR / EM316EDFA-LPR Monitored Parameters 
 
•  Input power and output power readings 
•  Output gain reading 
•  Case temperature reading 
•  Amplifier status reading 
• Alarm 
status 
o
 case 
temperature 
o
  loss of input power 
o
  loss of output power 
 
 
2.1.2 EDFA Control Inputs 
• Software 
reset 
•  Output power mute 
 
 
2.1.3 EDFA Alarm Outputs 
• Case 
temperature 
•  Loss of input 
•  Loss of output