MRV Communications EM316EDFA-LPR 사용자 설명서

다운로드
페이지 44
 
 
Fiber Driver
®
 EM316EDFA User Guide
 
 
P/N 1294008-001 Rev D2 
 
18 
 
5.2.4 Chassis Context 
 
Command examples in this section are applied in the chassis-level context. The box below 
shows the command to navigate to the chassis context from the login context. 
 
 
 
 
5.2.4.1  “show” 
 
The following CLI excerpt shows a Fiber Driver chassis system with an EDFA amplifier 
module and an EM316LNXNM-OT network management (NM) module. Notice that the EDFA 
module is listed in both slots 1.3 and 1.4. 
 
 
 
Use the command line “?” (help character, shown below) to display command line 
parameters for the show command. 
 
fiberdriver# configure terminal 
fiberdriver(config)# 
fiberdriver(config)# chassis 1 
fiberdriver(chassis/1)# 
fiberdriver(chassis/1)# show 
        Model: NC316BU-16 
         Name: NC316BU-1 
      Temp(C): 25 
  Temp Min(C): 5 
Temp Limit(C): 55 
 
PS1: DC Bad  PS2: AC Good 
Fan1: good  Fan2: good 
Fan3: good 
Chassis Traps: on  Slot Change Traps: on  Module Specific Traps: on 
   Port Traps: on         Link Traps: on         Loopback Traps: on 
    LIN Traps: on  Port Change Traps: on       Port Diags Traps: on 
 
Number Of Slots: 16 
Hardware Revision: 1 
 
Slot  Model            Name                    Serial Number 
====  ===============  ======================  
============================ 
1.2   EM316LNXNM-OT    EM316LNXNM-OT at 1.2    00:2
1.3   EM316EDFAv       EM316EDFAv at 1.3       N/A 
0:1a:02:48:28 
1.4   EM316EDFA        EM316EDFA at 1.4        N/A 
1.5   EM316E1MUX4RM    EM316E1MUX4RM at 1.5    12:34:56:78:90:15 
1.7   EM316EFE1MUXRJv  EM316EFE1MUXRJv at 1.7  00:20:1a:77:88:99 
1.8   EM316EFE1MUXRJ   EM316EFE1MUXRJ at 1.8   00:20:1a:77:88:99 
 
fiberdriver(chassis/1)#