dard 15 amp IEC receptacle at the rear of  the amplifier chassis.  Two 
XA200’s  may  be  run  on  a  single  15-amp  circuit.    This  amplifier  is 
equipped for operation with an earth ground provided by the users 
AC outlet. Never defeat this ground connection.  The signal ground 
of  this amplifier is connected to earth through a power thermistor, 
which provides a safety ground but provides protection from irritating 
ground loops.
As a safety issue we suggest that the power cord should be the last 
cable installed on your power-amplifier.  You may, if  you wish, substi-
tute a 15-amp aftermarket power cord for the one we have supplied. 
Only use power cords, which meet all local safety standards and carry 
acceptance marks from the local regulatory authority. The power cord 
should be attached to the amplifier prior to plugging into house power.  
Place the rear mounted switch in the off (down) position before plug-
ging in this amplifier. 
The  amplifier’s  voltage  and  current  rating  are  indicated  on  the  rear 
panel.  It will be either 240 volts, 220 volts, 120 volts or 100 volts, all 
with a restorable type circuit breaker of the appropriate ampacity. The 
inclusion of this re-settable circuit breaker does away with the need for 
disposable fuses.  The frequency rating of the AC line source is 50 to 
60 Hz in all cases.  Please verify that the amplifiers indicated voltage 
requirements are consistent with the supplied voltage and current at 
your location. Transformers are input voltage specific and their change 
is not a trivial matter.
Looking at the rear panel you will see the AC power cord receptacle, 
a power switch / breaker, two pairs of output connectors which allow 
for  speaker  bi-wiring,  a  single  pair  of  5  way  connectors  for  remote 
turn-on, a single RCA input connector and a single XLR balanced input 
connector.
Make  sure  that  the  rear  panel  power  switch/breaker  is  off  (down).  
Plug the AC cord into the back of the amplifier, and then into the wall.  
Then turn the power switch/breaker on (up).  The lights in your house 
will blink when the power supply charges the capacitors.  (Note: The 
power switch/breaker is never to be used as a “safety device” or “emer-
gency disconnect” for this product.  This device provides current limit-
ing which will protect the amplifier, it will not provide personal shock 
protection in the event of a reversed hot / neutral, lack of grounding 
or other improper wiring in the supplied mains voltage.)
On the front panel, the “Standby” LED indicator should be glowing 
blue, indicating that AC power is available and the capacitor banks are 
Setup