Dual XIA4225 사용자 설명서

다운로드
페이지 12
11
XIA4225
 OPERATION
Troubleshooting
Problem
Cause
Action
Unit will not turn on
(no power LED indicator)
+12V wire not connected or incorrect voltage 
REM wire not connected or incorrect voltage
Check connections for proper voltage 
(11~16VDC) 
GND wire not connected
Check connection to ground
Fuse(s) blown
Replace fuse(s)
Unit has power - LED is 
green (but no sound)
Speaker wires not connected
Check connections at speakers
Volume turned all the way down
Increase volume level at head unit
One or more speaker wires touching each 
other or touching chassis ground
Insulate all bare speaker wires from 
each other and chassis ground
Speaker(s) defective or damaged
Check/replace speaker(s) 
Input signal not connected
Check high or low level inputs for 
proper connection
Unit blows fuse(s)
Incorrect fuse rating
Use fuse(s) with correct rating
+12V wire touching chassis ground
Check for pinched wire
Speaker(s) defective or damaged
Check/replace speaker(s) 
Engine noise
Bad ground connection
Make sure amplifier is grounded to 
clean bare metal 
Signal ground loop or RFI  
(radio frequency interference)
Re-route RCA cables from existing 
high current wiring 
LED illuminates red
(protect mode)
One or more speaker wires touching each 
other or touching chassis ground
Insulate all bare speaker wires from 
each other and chassis ground
Speaker(s) defective or damaged internally 
(shorted)
Check/replace speaker(s) 
Speaker load less than 2 ohms (stereo)
Speaker load less than 4 ohms (bridged)
Adjust speaker load - amplifier will 
not operate at less than 4 ohms when 
bridged
Distorted audio output
Incorrect input signal type or input level too 
high 
Check connections and reduce/adjust 
input level
Low audio output
Incorrect input signal type or input level 
too low
Check connections and increase/
adjust input level
Weak bass 
Speaker(s) are wired out of phase
Check (+) and (-) speaker connections
(Observe correct polarity)
No illuminite output 
(no lights)
Fuse blown - illuminite output (+12VDC) wire  
touching ground
Check or replace fuse 
Use 2 amp ATO fuse only
illuminite (+) or (-) wires not connected
Check connections at speakers
illuminite connections wired wrong 
(reverse polarity)
Reverse (+) and (-) connections 
(Observe correct polarity)
illuminite speaker(s) defective or damaged
Check/replace speaker(s)