Installing Mirrored Systems 
CentreVu CMS Release 3 Version 8 Disk-Mirrored Systems
Factory installation procedures for disk mirroring
35
Step 8: Install the 
CMS software
2
Now you will complete the installation of the usual software by installing 
CMS. In general, the steps are as listed below. Detailed installation 
instructions can be found in 
CentreVu CMS R3V8 Software Installation 
and Setup (585-210-941).
The steps to be completed are these:
Install CMS software
Install CMS patches (if needed)
Install CMS Supplemental Services software
Set up CMS
Install Open Database Connectivity (ODBC) software (optional)
Set up the remote console
Administer the NTS (if using NTS ports)
Step 9: Create an 
alternate boot 
device
2
1. Enter the following command:
where 
newbootdev is the device name of the disk chosen as boot 
disk 2 (as c0t1d0s0, for example). You partitioned that disk earlier in 
the installation procedure.
The system responds (for example):
2. Record the device definition (the part after 
/devices
 and 
before
:a,raw). 
For the example above, you would record the part 
beginning 
/sbus@3,0 
and ending
 sd@1,0
.
3. Reboot the system by entering the following command:
The system displays the
 ok 
prompt.
4. Create a device alias for the new boot device by entering the 
following command (for example):
Replace 
<device> 
with what you recorded in item 2. For the 
example shown, you would replace 
<device> with the following:
/sbus@3,0/SUNW,fas@3,8800000/sd@2,0
#
ls
-l
/dev/rdsk/
newbootdev
lrwxrwxrwx   1 root     root          83 Jun 18 15:23 
/dev/rdsk/c0t1d0s0 -> ../../devices/sbus@3,0/SUNW,
fas@3,8800000/sd@1,0:a,raw
#
/usr/sbin/shutdown
-y
-i0
-g0
ok nvalias
bootdevice2
<device>