INSTALLATION 
Connections 
Two conductor  (four conductor for V-1060B 
only) twisted wire is required for the 45 Ohm 
talkback speakers.  Standard 22 or 24 gauge 
station wire is acceptable.  Shielded wire is not 
required or recommended. 
Connections are as follows: 
 
Speaker out from page control to speaker tip 
 
Speaker common to speaker ring 
 
For 1060B only: 
 
Switched -24VDC to -24VDC (LED) 
 
Power Supply ground to GND (LED) 
Mounting 
CEILING SPEAKERS:  Cut an 8.5" diameter 
hole in ceiling tile.  After connections have been 
made to the speaker, attach speaker to ceiling 
tile using the mounting hardware provided.  
NOTE:  Where extra speaker support is needed, 
a V-9916 or V-9916M Valcom Bridge and 
Backbox should be used. 
WALL SPEAKERS:  After making the required 
connections, fasten a suitable mounting screw 
(#10 sheet metal screw
 or similar) to the wall at 
the desired location for mounting of the speaker.  
Hang the speaker on the screw using the 
keyhole on the speaker bracket.
CORNER SPEAKERS:  After making the 
required connections to the speaker, use 
appropriate hardware such as an 8d finishing 
nail and hang the speaker in the corner.  Typical 
mounting height would be 8 feet.  
CORRIDOR SPEAKERS:  Unscrew mounting 
bracket and baffle from speaker assembly.  
Using appropriate hardware, mount the bracket 
to the wall.  After making the required 
connections, reattach the baffle to the speaker 
and the speaker to the mounting bracket. 
TECHNICAL ASSISTANCE 
When trouble is reported, verify there are no 
broken connections.  Troubleshooting 
assistance is available from the factory.  
Call (540) 563-2000 and press 1 for Technical 
Support, or visit our website at 
http://www.valcom.com. 
 
Valcom equipment is not field repairable.  
Valcom, Inc. maintains service facilities in 
Roanoke, VA.  Should repairs be necessary, 
attach a tag to the unit clearly stating company 
name, address, phone number, contact person 
and the nature of the problem.  Send the unit to:  
Valcom, Inc. 
Repair and Return Dept. 
5614 Hollins Road 
Roanoke, VA 24019-5056 
 
TROUBLESHOOTING CHART 
SYMPTOMS 
ACTIONS 
 
No sound in page mode 
 
Check tip and ring for audio at speaker. 
 
Check tip and ring for audio at control unit. 
 
Low sound in page mode 
 
Check volume controls at page control. 
 
Poor listening in talkback mode 
 
 
No LED indication (on V-1060B) 
 
Check talkback volume control at page control.  Set control where audio is 
clearly audible. 
 
Check presence and polarity of LED input signal. 
 
 
VALCOM LIMITED WARRANTY 
Valcom, Inc. warrants its products to be free from defects in materials and workmanship under conditions of normal use and service for a period of one 
year from the date of shipment.  The obligation under this warranty shall be limited to the replacement, repair or refund of any such defective device 
within the warranty period, provided that: 
 
1. 
inspection by Valcom, Inc. indicates the validity of the claim; 
2. 
the defect is not the result of damage, misuse or negligence after the original shipment; 
3. 
the product has not been altered in any way or repaired by others and that factory sealed units are unopened (A service charge plus parts 
and labor will be applied to units defaced or physically damaged); 
4. 
freight charges for the return of products to Valcom are prepaid; 
5. 
all units ‘out of warranty’ are subject to a service charge.  The service charge will cover minor repairs (Major repairs will be subject to 
additional charges for parts and labor). 
 
This warranty is in lieu of and excludes all other warranties, expressed or implied, and in no event shall Valcom, Inc. be liable for any 
anticipated profits, consequential damages, loss of time or other losses incurred by the buyer in connection with the purchase, operation or 
use of the product.
 
 
This warranty specifically excludes damage incurred in shipment.  In the event a product is received in damaged condition, the carrier should be notified 
immediately.  Claims for such damage should be filed with the carrier involved in accordance with the F.O.B. point. 
Headquarters: 
Valcom, Inc. 
5614 Hollins Road 
Roanoke, VA 24019-5056 
Phone:  (540) 563-2000 
FAX:  (540) 362-9800