Installing the Simplese System in Your Home
I.
  
Prewire
 
The Simplese System uses CAT5 cable for keypad control and either two or four-conductor 16-gauge speaker wire. All the wire is 
“homerun” from each zone to the location of the Allport connection hub.
Complete CAT5 Crimping Instructions
The NuVo audio systems require CAT5, unshielded, twisted 
pair (UTP), for communication between the 
keypads/Display Pads and the main amplifier unit. Each 
end of the wire is terminated with an RJ45 connector.
The Simplese System can accommodate 2000 total feet of 
CAT5 cable. For the most reliable operation, it is best that 
no single run of CAT5 exceeds 250 feet.
The correct wiring scheme for the CAT5 cable is standard 
EIA/TIA 568A. Properly terminating the CAT5 cable is 
crucial for the operation of the system. It is very important 
to use a good quality crimp tool, and testing each end to 
end run  with a CAT5 wire tester will insure that your 
system operates flawlessly, fig.1.
Step-by-Step Crimping Instructions
 1. 
Strip a 2 to 3 inch portion of the insulation,         
exposing the 4 twisted pairs.
2.  
Untwist the wires and fan them out 
individually.  Arrange the wires into the 
correct color scheme as shown in Fig. 1.
3. 
Flatten the wires in their correct order, and  trim 
them evenly across the top. Most crimp tools have 
a wire trimmer built-in. It is best to trim the wires 
to about ½” in length.  
4.  
While holding the wires flat between your thumb 
and forefinger, insert the wires into the RJ45 
connector, so each is in its own slot. Push the wire 
into the RJ45, so all 8 conductors touch the end of 
the connector. The insulation jacket should 
extend beyond the crimp point of the RJ45.
5.  
Insert the RJ45 into the crimp tool receptacle and 
squeeze the tool firmly. Note that a ratchet type 
tool should tighten down until it no longer clicks.
6.  
The RJ45 should be firmly crimped to the CAT5 
insulation. It is necessary that the color scheme 
be repeated identically on each end of the wire.
Fig. 1:  EIA  568A wiring scheme for CAT5 Cable
Pin #
1.  Green Stripe
2.  Green
3.  Orange Stripe
4.  Blue
5.  Blue Stripe
6.  Orange
7.  Brown Stripe
8.  Brown
Note:  Colors listed as “stripe” are  a white wire
with a colored stripe.
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
1 2 3 4 5 6 7 8
Top view with 
tab down.
Wires insert from 
this end.
Pair 2
Pair 3
Pair 4
Pair 1
IR
 S
ig
n
a
- S
o
u
rc
1
G
ro
u
n
d
C
o
n
tr
o
D
a
ta
 B
u
s-
C
o
n
tr
o
D
a
ta
 B
u
s+
IR
 S
ig
n
a
- S
o
u
rc
2
G
ro
u
n
d
+1
2V
 P
o
w
er
G
ro
u
n
d