INSTALLER
MAKING CONNECTIONS
12VDC Mute Trigger In/Trigger Out
Doorbell Interface
12VDC Power Supply
R235LS Amplifier
12VDC Mute Trigger In
When 12VDC is applied to the Mute In, the 
system will fully mute all zones in the system.
The connections for the trigger are made using a
two-conductor cable with 1/8” male mini-plug
jacks. The tip is positive (+) and sleeve is nega-
tive (-). This allows for the connection of an exter-
nal paging or muting device. Note: The CAS44
will not accept a paging audio input; however, if
used with an independent paging system with
12V trigger out, that can be used to trigger the
mute. 
12VDC System Trigger Out
Trigger Out 12VDC output is used for triggering
an external amplifier or other component. The
connections for the output are made using a
two-conductor cable with 1/8” male mini-plug
jacks at each end. The tip is positive (+) and
sleeve is negative (-). The System Trigger Out
supplies 12VDC when the first keypad is turned
on. The 12 VDC is removed 5 minutes after the
last keypad is turned off.