TOA Electronics VM-2120 사용자 설명서

다운로드
페이지 72
50
Connected unit No. table (SW3) 
* The total number of one Sub-VM amplifier and up to 4
Remote Microphones (excluding the Master amplifier
and Remote Microphone Extension) 
SW4 switch setting (Both switches are factory-preset to ON position.) 
* Determines the attenuation level when the broadcast of higher priority (level 2 or 3) overrides the BGM
broadcast (priority level 4). (See p.27 "GENERAL-PURPOSE BROADCAST PRIORITY) 
23.3. Remote Microphone's Function Switches 
* One of 2 priorities can be set for each Remote microphone. (See p.27 "GENERAL-PURPOSE
BROADCAST PRIORITY.") 
RM (RM-200M) Unit No. table 
All switches No. 1 – 6 are factory-preset to the ON position.
Switch No. 
No. of Connected Units* 
6 7 8 
OFF OFF OFF 
ON OFF OFF 
OFF ON OFF 
ON ON OFF 
OFF
OFF
ON 4 
ON
OFF
ON 5 
Switch No. 
BGM broadcast volume attenuation* 
1 2 
OFF 
OFF 
No attenuation 
ON 
–28 dB (just audible) 
ON
Don't care 
dB (inaudible) 
Compressor 
On 
Off 
1 2
ON
3 4 5 6
Function setting switch (No.23)
Note
The switch is actually installed upside down.
Switch No. 
Function 
ON 
OFF 
1
RM Unit No. 
(See the RM Unit No. 
table below.)
Broadcast 
Priority* 
Talk key 
operation
Press-to-talk 
type 
Talk lock type 
Emergency 
switch
Enable 
Disable
RM Unit No. 
No. 1
No. 2
No. 3
No. 4
Switch No. 
1
2
ON
ON
OFF
ON 
ON
OFF
OFF
OFF