JAI TM/TMC-4200CL 사용자 설명서

다운로드
페이지 70
Page 44
Functions and Operations
TM/TMC-4200CL Series Progressive Scan Cameras
TABLE 6.
Asynchronous Mode Chart
6.5 Dynamic Range Control 
FIGURE 59.
Output and Blooming
The typical interline transfer CCD has fixed noise levels based on dark current (thermal or KT noise), 
pattern noise, and the operating clock speed. In general, the level of the 20 MHz pixel clock CCD at 
room temperature is around 20 to 50 electrons. The maximum capacity of CCD charges is limited by the 
well capacity at saturation. The range is limited by the structure and the pixel size. 
The TM-4200CL uses a CCD with 7.4 µm x 7.4 µm pixel and two-phase vertical shift register structure. 
The well capacity is 40,000 electrons. The theoretical dynamic range is 40,000:30 = 1333:1 (60 dB).
Async no Shutter
Async Preset and Prog. Shutter
PWC
aA
<1 line
<1 line
6 clk
aB
9.5 line
(n + 1) lines + 1024 clk
Pulse width + 1024 clk
aC
1024 clk
PIV Fixed Expo
PIV PWC
Unit
pA
6
6
Pixel
pB
200
200
pC
160
160
pD
320
320
pE
20
20
pF
1
1
Frame
0
20
40
100
60
120
80
0
200
400
600
FL
Lens: F=5.6
Vsub = 10 V
Vsub = 12 V
Vsub = 14 V
Vsub = 16 V
Vsub = 18 V
CCD OUTPUT VOLTAGE 
LUMINANCE
Blooming adj. = 13. 5 V
Digital saturation at 16 dB amp
Analog saturation at 20 dB amp
Max. Digital dynamic range at 3 dB amp
140
160
mV
Vsub = 8 V