JAI CV-M77 사용자 설명서

다운로드
페이지 28
CV-M77
 
 
C - Gain and analogue signals settings. 
1 AGC switch 
AS=[Param.]<CR><LF> 
AS?<CR><LF> 
0=OFF (Manual), 1=ON (Auto) 
 
2  Master gain level 
GA=[Param.]<CR><LF> 
GA?<CR><LF> 
0-700 Available 
when 
AS=0. 
3  Red gain level 
RG=[Param.]<CR><LF> 
RG?<CR><LF> 
0-255 Available 
when 
WB=0. 
4  Blue gain level 
BG=[Param.]<CR><LF> 
BG?<CR><LF> 
0-255 Available 
when 
WB=0. 
5 AGC level 
AG=[Param.]<CR><LF> 
AG?<CR><LF> 
0-255 Available 
when 
AS=1. 
6 White balance 
WB=[Param.]<CR><LF> 
WB?<CR><LF> 
0=Manual (Variable) 
1=Auto (Variable) 
2=4600K (Fixed) 
3=5600K (Fixed) 
Sets manual gain values 
(RG, BG) when changed 
to 0 from other selections.  
7  Auto white balance 
AW=[Param.]<CR><LF> 
0=One push auto white balance 
Available when WB=1. 
8  Master setup level 
SU=[Param.]<CR><LF> 
SU?<CR><LF> 
33-223
 
(default = 128) 
 
9  Red setup level 
RS=[Param.]<CR><LF> 
RS?<CR><LF> 
96-160
 
(default = 128) 
 
10 Blue setup level 
BS=[Param.]<CR><LF> 
BS?<CR><LF> 
96-160
 
(default = 128) 
 
11 White clip level 
WC=[Param.]<CR><LF> 
WC?<CR><LF> 
0-1023 
 
12 Gamma select 
GS=[Param.]<CR><LF> 
GS?<CR><LF> 
0=1, 1=0.45, 2=0.6 
 
D - saving and loading data in EEPROM 
Load settings 
(from camera 
EEPROM) 
LD=[Param.]<CR><LF> 
0=FACTORY DATA AREA 
1=USER DATA AREA 
Save settings 
(to camera EEPROM) 
SA=[Param.]<CR><LF> 
1=USER DATA AREA 
Latest used DATA AREA 
becomes default at next 
power up. 
Save settings into 
Factory Area. 
SA00=[Param.]<CR><LF>  0=FACTORY DATA AREA 
Not disclosed for user. 
EEPROM Current 
Area No. Request 
EA?<CR><LF> 
0=FACTORY DATA AREA 
1=USER DATA AREA 
 
 
 
7.3.1  Receiving Data (Camera->PC) 
 
 
If the function succeeds, the return value is a handle to the newly allocated memory object.  If the 
setting succeeds, returned is the below word from the camera. 
 
COMPLETE<CR><LF> 
 
Error Messages: 
• 
Command Error: 
01 Unknown Command!!<CR><LF> 
• 
Parameter Error: 
02 Bad Parameters!!<CR><LF> 
 
 
Response to Request Command 
Example: 
 
Request Command (PC→Camera) 
Command Name 
Format 
Receiving Data(Camera→PC) 
Remarks 
Trigger Mode 
TR?<CR><LF> 
TR=[Param.]<CR><LF> 
"Param." is same as 
setting command. 
 
- 17 -