Installing the Vehicle Imaging Subsystem
 
Arrow down – negative going 
As a guideline the two LEDs marked TRIG-0 and TRIG-1 shall be off when no trigger pulse is present. 
3.3.5 (b) Test Trigger 
Activating switches S1 and S4 generates a trigger pulse for test purposes. Only one trigger pulse is 
generated each time the switch is activated. 
The duration of the trigger pulse is approximately 4 ms. 
The trigger indicator LEDs flash when the test trigger switch is activated. 
Figure 24.  Test trigger 
 
3.3.6  X15 Lane Controller Connector (X4 and X5) 
The Lane Controller connection to the J-Panel is connector X15. The connections are listed in Table 
8 . 
Table 8 
X15 Lane Controller 
X15 Pin # 
Signal 
Description 
Connection to 
D0+ 
RS485 databus D0+ 
Lane Controller databus 0+ 
D0- 
RS485 databus D0- 
Lane Controller databus 0- 
3 Gnd gnd 
gnd 
D1+ 
RS485 databus D1+ 
Lane Controller databus 1+ 
D1- 
RS485 databus D1- 
Lane Controller databus 1- 
 
It is possible to have one Lane Controller connected to several cameras or one Lane Controller to 
each camera: 
One Lane Controller for two or more cameras 
1. The Lane Controller is connected to the X15 pin 1 and 2 (no connections to pin 4 and 5) 
2. Switch S2 position “OPEN” 
3. The Lane Controller can be connected to more J-Panels by connecting RJ45 patch cables between 
connector X4 and connector X5 on the next J-Panel (and from X4 on the next J-Panel to X5 on the 
third J-Panel). Switch S2 on the other J-Panels must also be in the “OPEN” position. 
Two Lane Controller to two cameras 
1. The Lane Controller for camera 0 is connected to X15 pin 1 and 2 
2. The Lane Controller for camera 1 is connected to X15 pin 4 and 5 
3. Switch S2 position “TERM” 
4. Do not connect any cables to X4 and X5