7.4. RS-232C control 
All configuration of the CV-M4
+
 camera is done via the RS-232C port. On the 12 pin Hirose 
connector, if JP301 is open, or via Camera Link if JP301 is short. The camera can be set up from 
a PC running terminal emulator software, or using JAI´s camera control software.  
Below is the description of the ASCII based short command protocol. 
 
Communication setting.  
 
TXD
RXD
GND
1 CD
4 DTR
6 DSR
2 RXD
3 TXD
5 GND
7 RTS
8 CTS
9 CI
9 pin
D-con
PC COM
PORT 
CAMERA
TXD
RXD
GND
1 CD
4 DTR
6 DSR
2 RXD
3 TXD
5 GND
7 RTS
8 CTS
9 CI
9 pin
D-con
PC COM
PORT 
CAMERA
Baud Rate 
9600 bps 
 Data Length 
8 bit 
Start Bit 
1 bit 
Stop Bit 
1 bit 
Parity None 
Xon/Xoff Control  None 
 
 
 
RS 232C cable 
  
Protocol. 
 
Transmit setting to camera: 
NN=[Parameter]<CR><LF>  (NN is any kind of command. Capital or small letters.) 
The camera answers: 
COMPLETE<CR><LF> 
 
To have all communication on the emulator screen, start with: 
 
EB=1<CR><LF> 
The camera answers: 
COMPLETE<CR><LF> 
 
Transmit request command to camera: 
NN?<CR><LF>  (NN is any kind of command.) 
The camera answers: 
NN=[Parameter]<CR><LF>  
 
Transmit the following to have the camera actual setting: 
ST?<CR><LF> 
The camera answers: 
A complete list of the current settings   
 
Transmit the following to have a command list: 
HP?<CR><LF> 
The camera answers: 
A list with all commands and possible settings 
 
 
Invalid parameters send to camera: 
SH=99<CR><LF>   
The camera answers: 
02 Bad Parameters!!<CR><LF> 
 
When the camera is set in “Off Line” (SW1-10 on rear to Local) 
 
NN=[Parameter]<CR><LF>  
The camera answers: 
03 Offline!!<CR><LF>