7.2. CV-A50/60 RS-232C command list. 
 
 
Command Name 
Format 
Parameter 
 
Remarks 
      A – General settings and useful commands 
EB  
Echo Back 
EB=[Param.]<CR><LF>  0=Echo off 
1=Echo on 
Off at power up 
ST  Camera Status request  ST?<CR><LF> 
 
 
Actual setting 
HP  Online Help request HP?<CR><LF> 
 
 
Command list 
VN  Firmware version 
VN?<CR><LF> 
 
 
3 letter version 
      B – Timing and shutter related commands 
SC  
Scanning format 
SC=[Param.]<CR><LF>  0=Interlaced  
2=1/2 partial 
1=Non-interl. 
3=1/3 partial 
Partial scanning is 
not supported 
TR  Trigger mode 
TR=[Param.]<CR><LF>  0=normal 
2=Pulse width 
4=Long time 
1=Edge 
3=Frame delay 
5=Start/stop 
 
SM  Shutter mode 
SM=[Param.]<CR><LF>  0=Normal 1=Programmab. 
 
SH  Shutter speed 
SH=[Param.]<CR><LF>  0=Off 
 
0=1/50 (1/60) 
2=1/250 
4=1/1000 
6=1/4000 
1=1/100 
 
1=1/125 
3=1/500 
5=1/2000 
7=1/10000 
Continuous only 
 
 
Trigger modes and 
Continuous  
 
PE  Programmable expos. 
PE=[Param.]<CR><LF>  0= No function 
1023=1023.5H 
1=1.5H 
 
CCIR. H=64µsec 
EIA, H=63.5µsec 
*1) 
      C – Signals and polarity 
FR  
Accumulation 
FR=[Param.]<CR><LF>  0=Field  
1=Frame 
 
PC  Pixel clock 
PC=[Param.]<CR><LF>  0=no clock out 
1=clock out 
Should be off 
when not used 
TP  Trigger polarity 
TP=[Param.]<CR><LF>  0= active low 
1= active high 
*2) 
WP  WEN polarity 
WP=[Param.]<CR><LF>  0= active low 
1= active high 
 
      D – Gain and analogue signals setting 
AS  
AGC Switch 
AS=[Param.]<CR><LF>  0=AGC off 
1=AGC on 
0= manual gain 
AG  AGC Level 
AG=[Param.]<CR><LF>  0=low 255=high 
Range 0 to 255 
GA  Manual gain Level 
GA=[Param.]<CR><LF>  0=low 255=high 
Range 0 to 255 
RP  Rear Potentiometer 
RP=[Param.]<CR><LF>  0=manual gain 
1=rear potm. 
 
SU  Setup Level 
SU=[Param.]<CR><LF>  0=low 255=high 
Range 0 to 255 
WC  White clip Level 
WC=[Param.]<CR><LF>  0=low 255=high 
Range 0 to 255 
GS  Gamma Select 
GS=[Param.]<CR><LF>  0=gamma 1 
1=gamma 0.45 
 
      E – Saving and loading data in EEPROM 
LD  
Load settings from 
camera EEPROM 
LD=[Param.]<CR><LF>  0=Factory data  
2=User 2 area 
1=User 1 area 
3=User 3 area 
Latest used data 
area becomes 
default at next 
power up 
SA  Save settings to 
camera EEPROM 
SA=[Param.]<CR><LF>  1=User 1 area 
3=User 3 area 
2=User 2 area 
 
 
*1) 
In normal non trigger mode (TR=0) PE<312 for CCIR and PE<262 for EIA. In trigger mode TR=1, EEN will not be correct if 
PE>833.  
*2) 
If positive logic is used (TP=1), the first trigger pulse after power up will be ignored. 
!! 
Do not try to use commands not shown in the list. 
 
 
 