Installing the Vehicle Imaging Subsystem
 
Figure 22.  X-6 Power input connection. 
 
 
3.3.4  X8 LS RS485 Out Connector 
The RS485 output from the Light Sensor to the RS485-to-Ethernet converter connector is X8. The 
connections from X8 to the converter are shown in Table 6 and Figure 23 
Table 6 
X8 to converter connector 
X8 Pin #  Signal 
Description 
Connection to RS485-to-Ethernet converter 
+24V dc 
24V Power output 
V+ power input 
2 Gnd Power 
return 
V- power input 
+12V dc 
12V Power output 
 
4 Gnd Power 
return 
 
D0+ 
RS485 databus D0+ 
D+ Port 2 
D0- 
RS485 databus D0- 
D- Port 2 
D1+ 
RS485 databus D1+ 
D+ Port 1 
D1- 
RS485 databus D1- 