Sanyo VCC-MD500 사용자 설명서

다운로드
페이지 42
− 28 −
Optical Zoom Limit Settings
The optical zoom magnification can be limited using 
the Optical Zoom Tele Limiter command. The digital 
zoom cannot be used if the limit is set to the Tele side.
Digital Zoom
A maximum of 16x digital zoom can be set with the 
Digital Zoom Tele Limiter command. Together with 
the optical zoom, a maximum of 480x is possible, 
however, the resolution decreases.
Although the vertical resolution can be increased by 
enabling the V-Reso.UP function using the V-Reso.
UP ON command, residual images and blurring may 
become more apparent with moving subjects.
[2]  Focus Control
Manual Focus
The manual focus can be operated using Far/Near or 
directly moving the focus to a specific position.
Far /Near
 
Transmit the Far or Near command to execute the 
Far/Near operation at the speed configured by the 
Far/Near Speed command. The Stop command 
stops the operation. (The operation does not stop 
without transmitting the Stop command.)
The speed targets are as follows.
Settings
Required Time (s) from Near End  Far End  
at the Near Limit 1m and Tele End
x36  MD700 
 
MD800
x30  MD500 
 
MD600
x22  MD300 
 
MD400
1
19.7
16.0
19.0
2
10.3
8.3
9.7
3
4.4
3.6
6.6
4
2.4
2.1
5.2
Direct
 
The Direct command can move the zoom lens to the 
specified focus lens position.
Auto Focus
 
The Auto Focus ON command sets the mode to auto 
focus and automatically focuses on the subject if 
the subject moves. This mode is cancelled when the 
Manual Focus ON, Near, or Far command is used.
Although the minimum focus distance is set to 1m by 
default, this can be changed by using the Near Limiter 
command. In addition, the sensitivity of the AF to the 
change in subject can be changed using the Auto 
Focus Sensitivity command and the focusing area can 
be changed using the Focus Area command.
One-Push Auto Focus
The auto focus can be moved only once using the 
One Push Trigger command. The mode prior to 
starting the auto focus is retained after focusing.
Focus Lens Offset
When covering a camera, such as the dome camera 
with a cover or similar, the refraction of the light due to 
the cover changes the OPL. This may result in close 
subjects being out of focus when using a powerful 
zoom.   
In that case, it is necessary to move the range of 
motion of the focus lens depending on the change in 
OPL.
Validate the Offset using the Cover Offset ON 
command and transmit a Cover Offset Level 
command so that subjects that are at approximately 
1m TELE edge (When the Near Limit is 1m) are in 
focus. 
In the same way that 0 sets the level to OFF, the 
larger the number, the greater the offset. 
[3]  White Balance Control
ATW
 
Auto Trace White Balance.
SMART ATW
 
This mode controls retracing of ATW according
 
 to the size of single-colour object in the screen, 
 
addition to normal ATW mode control.
 
In case the single-colour object covers most of 
 
the area in the screen, WB control function shall 
 
be stopped.
 
Also, the retracing speed is slower than that of 
 
normal ATW mode.
  
*This mode is valid when WB mode is set to ATW.
AWC
 
The Push-Lock Auto White Balance starts retracting 
using the One Push Trigger command and locks the 
white balance after approximately 2 seconds.
In addition, after executing the One Push Trigger 
command, the mode returns to the previous mode 
by executing the AWC Reset command.
3200K
 
Color temperature 3200K fixed mode.
5600K
 
Color temperature 5600K fixed mode.
FLUO
 
Color temperature 4200K fixed mode. 
MWB
 
Manual White Balance. The R and B gains can each 
be configured to a range of 0 to 255.
Function Descriptions