Sanyo VCC-MD500 사용자 설명서

다운로드
페이지 42
− 33 −
Setting the Mask Position (Area Mask Position Set)
x-Coordinate 
Start Position
x-Coordinate 
End Position
y-Coordinate
Start Position
y-Coordinate
End Position
x
y
If the coordinates increase by 1, the position moves 
by 4 horizontal pixels and 2 vertical lines.
The upper left and lower right horizontal and vertical 
coordinates (1 byte each) are each divided into upper 
and lower 4 bits.
Example)  Setting the mask position according to the 
following parameters during NTSC
Mask Number
1
x-Coordinate Start Position
0x48
y-Coordinate Start Position
0x1C
x-Coordinate End Position
0x82
y-Coordinate End Position
0x40
Pan Angle
135°
Tilt Angle
45°
Setting Procedures
1.  Mask Position (x, y coordinates) Settings 
(Area Mask Position Set) 
A0 10 09 01 04 08 01 0C 08 02 04 00 CS FF
2.  Mask Angle Settings (only during PTZ) 
(Area Mask Degree Set) 
A0 10 11 01 05 04 06 01 0C 02 CS FF
3.  Setting Mask ON (Area Mask ON) 
A0 10 01 01 CS FF
Settings Increasing Privacy Mask Accuracy 
(MD800-MD500)  
Area Mask Position Center Set
Command:  A0 10 0A 0p 0q 0r 0s 0t CS FF
Parameter:
p
Mask Number (No. 1-15)
qr
Mask Width
st
Mask Height
Usage: Sets the mask position mainly according to the 
optical.
Note:  Set the mask size to sufficiently cover the mask 
object. In addition, ensure that the settings are 
set on the WIDE end. 
The minimum unit of the mask width is 4 
horizontal pixels and the minimum unit of the 
mask height is 2 vertical lines.
Mask Height
Mask Width
x
Example)  Setting the mask position according to the 
following parameters during NTSC 
Mask Number
1
Mask Width
0x50
Mask Height
0x3C
Pan Angle
135°
Tilt Angle
45°
Setting Procedures
1.  Mask Position (width and height) Settings 
(Area Mask Position Center Set) 
A0 10 0A 01 05 00 03 0C CS FF
2.  Mask Angle Settings (only during PTZ) 
(Area Mask Degree Set) 
A0 10 11 01 05 04 06 01 0C 02 CS FF
3.  Setting Mask ON (Area Mask ON) 
A0 10 01 01 CS FF
Function Descriptions