Sanyo VCC-MD500 사용자 설명서

다운로드
페이지 42
− 7 −
Communications Protocol
[2]  Communications Flow
Note: ◦Start the transmission of the next data after 
confirming the response command.
 
◦The maximum transmission interval of the 
various byte data is 500 [msec]. If this is 
exceeded, a communication error is detected 
in the camera unit, the receiving data is 
deleted, and data from the header is waiting 
to be received again. Furthermore, there are 
no special regulations regarding the minimum 
value.
 
◦ All the commands can be acquired after the 
periods below after start-up.  
 
MD600(P), MD500(P): 6 seconds
 
MD800(P), MD700(P): 9 seconds
 
When auto pixel defect compensation is set to  
 
ON, below period will be added to above at  
 
the longest. 
 
MD600(P), MD500(P): 15seconds
 
MD800(P), MD700(P): 20seconds
 
In factory default, Auto pixel defect  
 
 
compensation is set to OFF at start-up.
1 During Settings Command
Transmission
Source
Transmission 
Destination (Unit)
Header
Message 1
Message 2
Checksum
Terminator
Response Command
Settings Command
Transmissions
Repeats the byte 
count and the message 
and response commu-
nications in response 
to the contents of the 
message.
2 During Query Command (Other than ACK)
Response Command 
(NACK/ERR)
Query Command 
Transmissions
Repeats the byte 
count and the message 
and response commu-
nications in response 
to the contents of the 
message.
Transmission
Source
Transmission 
Destination (Unit)
Header
Message 1
Message 2
Checksum
Terminator
3 During Query Command (ACK)
Response Command 
(ACK)
Header
Message 1
Message 2
Checksum
Terminator
Query Command 
Transmissions
Query Command 
Response
Transmission
Source
Transmission 
Destination (Unit)
Header
Message 1
Message 2
Checksum
Terminator
Repeats the byte 
count and the message 
and response commu-
nications in response 
to the contents of the 
message.
Repeats the byte 
count and the message 
and response commu-
nications in response 
to the contents of the 
message.