Lucent Technologies 8.2 사용자 설명서
DEFINITY ECS Release 8.2
Administrator’s Guide
Administrator’s Guide
555-233-506
Issue 1
April 2000
Handling incoming calls
144
Setting up night service
7
Setting up trunk group night service
You can use trunk group night service if you want to direct individual trunk
groups to night service. The system redirects calls from the trunk group to the
group’s night service destination.
groups to night service. The system redirects calls from the trunk group to the
group’s night service destination.
Trunk group night service overrides night station service. For example, let’s say
you activate trunk group night service, and then your attendant activates night
station service. In this case, calls to the trunk group use the trunk night service
destination, rather than the station night service destination.
you activate trunk group night service, and then your attendant activates night
station service. In this case, calls to the trunk group use the trunk night service
destination, rather than the station night service destination.
Instructions
Let’s direct night calls for trunk group 2 to extension 1245.
To set up trunk group night service:
1. Type
change trunk-group 2
and press
RETURN
.
The
Trunk Group
screen appears.
2. Type
1245
in the Night Service field.
The destination can be a station extension, a recorded announcement
extension, a vector directory number, a hunt group extension, a terminating
extension group, or attd if you want to direct the call to the attendant.
extension, a vector directory number, a hunt group extension, a terminating
extension group, or attd if you want to direct the call to the attendant.
3. Press
ENTER
to save your changes.
TRUNK GROUP
Group Number: 2
Group Type: co
CDR Reports: y
Group Name: outside calls
COR: 1_ TN: 1__
TAC: ____
Direction: two-way_ Outgoing Display? n
Dial Access? n
Dial Access? n
Busy Threshold: 99
Night Service: 1245
Queue Length: 0
Country: 1_
Incoming Destination: _____
Comm Type: voice
Auth Code? n Digit Absorption List: _
Prefix-1? y Trunk Flash? n
Toll Restricted? y
BCC: _
TRUNK PARAMETERS
Trunk Type: loop-start
Outgoing Dial Type: tone
Trunk Type: loop-start
Outgoing Dial Type: tone
Cut-Through? n
Trunk Termination: rc
Disconnect Timing(msec): 500_
Auto Guard? n Call Still Held? n Sig Bit Inversion: none
Analog Loss Group: ___
Digital Loss Group: ___
Trunk Gain: high
Bit Rate: 1200
Synchronization: _____
Duplex: ____
Disconnect Supervision - In? y Out? n
Answer Supervision Timeout: 10
Answer Supervision Timeout: 10
Receive Answer Supervision? n