9-407
CLSFY-PT (Call Classifier Port)
9
Tone Detection Verification Test (#42)
This test checks the operation of the TN744 in touch-tone receiver, call classifier
and R2-MFC modes. It verifies the circuit pack’s ability to detect DTMF, ring
back, busy reorder and modem answer tones and to generate and detect
forward and backward MFC tones.
and R2-MFC modes. It verifies the circuit pack’s ability to detect DTMF, ring
back, busy reorder and modem answer tones and to generate and detect
forward and backward MFC tones.
Table 9-172.
TEST #42 Tone Detection Verification Test
Error
Code
Code
Test
Result
Description/ Recommendation
none
ABORT
The system was not able to allocate all the resources needed for this test
OR there was an internal system error.
OR there was an internal system error.
1
ABORT
The system could not allocate all the resources needed to test the tones.
1001
ABORT
The system was unable to put the call classifier port in the appropriate
mode to test it.
mode to test it.
1002
ABORT
The system could not allocate time slots for the test connection. This
situation could occur when the system is heavily loaded. If the system is not
heavily loaded, then test the TDM-BUS via the test tdm command.
situation could occur when the system is heavily loaded. If the system is not
heavily loaded, then test the TDM-BUS via the test tdm command.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
1003
ABORT
The system could not allocate a Tone-Clock for the test connection. This
may be caused by a heavy load on the system or by a faulted Tone-Clock.
may be caused by a heavy load on the system or by a faulted Tone-Clock.
1. Check to see if there are any alarms against the Tone-Clock in the port
2. If a new Tone-Clock has been inserted, allow about 1-minute for
maintenance to run on the newly inserted circuit pack.
3. Retry the command at 1-minute intervals for a maximum of 5 times.
2000
ABORT
Call classifier circuit pack’s response to the test request was not received
within the allowable time period.
within the allowable time period.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
2006
ABORT
Indicates that the active Tone-Clock circuit pack or a Tone Detector circuit
pack may not be functioning properly.
pack may not be functioning properly.
1. Test the
active Tone-Clock circuit pack in the port network with the test
tone-clock UUC command and refer to the TONE-BD section for
failures.
failures.
2. Retry the command at 1-minute intervals for a maximum of 5 times.
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
Continued on next page