Maintenance Object Repair Procedures
9-733
DUPINT (Duplication Interface Circuit Pack)
9
active and standby SPE carriers. Then, if all DUPINT and DUP-CHL alarms are
retired, a release of the standby SPE will allow memory shadowing to be turned
back on (if no further alarms pertinent to memory shadowing are present) and
refresh to complete. See STBY-SPE for more details as to how the turning on/off
of shadowing is controlled.
retired, a release of the standby SPE will allow memory shadowing to be turned
back on (if no further alarms pertinent to memory shadowing are present) and
refresh to complete. See STBY-SPE for more details as to how the turning on/off
of shadowing is controlled.
Error Log Entries and Test to Clear Values
Notes:
a. Indicates either a failure during a reset of the Duplication Interface circuit
pack, or a report that either or both of the HFAIL and STDONE bits are in
the wrong state. These errors cause a MINOR alarm that does not affect
memory shadowing. The Aux Data indicates which error occurred.
the wrong state. These errors cause a MINOR alarm that does not affect
memory shadowing. The Aux Data indicates which error occurred.
Table 9-281.
Duplication Interface Circuit Pack Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
Level
1
1.
DUPINT alarms can be resolved only when the alarmed Duplication Interface circuit pack is in the
active SPE carrier.
active SPE carrier.
On/Off
Board
Test to Clear
Value
0
0
Any
Any
Any
1
Control Register test (#865)
MAJOR
ON
test dupl l
257
Any
Mailbox Loop-around test (#866)
MAJOR
ON
test dupl l
513
Any
Local Loop-around test (#867)
MAJOR
ON
test dupl l
769
Any
Memory Shadowing Bounds Test
(#868)
(#868)
MAJOR
ON
test dupl l
2049 (a)
Any
Active DUPINT Reset Test (#870)
Active DUPINT STDONE/ HFAIL Check
Test (#979)
Active DUPINT STDONE/ HFAIL Check
Test (#979)
MINOR
ON
test dupl l
3073 (b)
2
None
MINOR
ON
test dupl l c
3329 (c)
Any
None
MAJOR
ON
test dupl l c
Aux
Data
Cause of Error
None
The active DUPINT Reset Test failed because the reset was
unsuccessful.
unsuccessful.
1
The STDONE bit is in the wrong state.
2
The HFAIL bit is in the wrong state.
3
The STDONE and HFAIL bits are both in the wrong state.