DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-1777
TIME-DAY (Time of Day) 
9
3. Test the active TN1648 SYSAM circuit pack using the test maintenance [a 
| b] sh command. If any tests fail, refer to the repair procedures for the 
SYSAM circuit pack before further investigating time-of-day problems. If 
all tests PASS and the alarm has not been retired, proceed to Step 4.
4. Replace the active TN1648 SYSAM circuit pack must be replaced. See 
 in Chapter 5. The alarm should be resolved 
within 15 minutes of replacing the SYSAM and resetting the time with set 
time
.