Lucent Technologies Release 6 사용자 설명서
DEFINITY Enterprise Communications Server Release 6
Installation and Test for Multi-Carrier Cabinets
Installation and Test for Multi-Carrier Cabinets
555-230-112
Issue 5
May 1998
Install and Connect Cabinets
Page 1-29
Fiber Optic Interconnect Cabling
1
Fiber Optic Interconnect Cabling
Signals between the cabinets are carried by fiber optic cables. Lightwave
transceivers provide the required fiber optic interface.
transceivers provide the required fiber optic interface.
The fiber optic cables from the DEFINITY System route to a Lightguide
Interconnect Unit (LIU) or fiber optic shelf. Refer to
Interconnect Unit (LIU) or fiber optic shelf. Refer to
Appendix A, ‘‘Connecting
Fiber Optic Cables’’
. Refer to this information for fiber optic equipment comcode
numbers, connecting to LIUs or shelves, and routing through lightguide
equipment.
equipment.
Use multi-mode fiber transceivers and multi-mode fiber optic cables between
cabinets unless single-mode fiber is required (distance restrictions). Use metallic
cables between carriers.
cabinets unless single-mode fiber is required (distance restrictions). Use metallic
cables between carriers.
!
CAUTION:
The DEFINITY ECS may contain a Class 1 LASER device if single-mode
fiber optic cable is connected to a remote Expansion Port Network (EPN).
The LASER device operates within the following parameters:
fiber optic cable is connected to a remote Expansion Port Network (EPN).
The LASER device operates within the following parameters:
■
Maximum Power Output: -5 dBm
■
Wavelength: 1310 nm
■
Mode Field Diameter: 8.8 microns
CLASS 1 LASER PRODUCT
IEC 825 1993
IEC 825 1993
!
CAUTION:
Use of controls or adjustments or performance of procedures other than
those specified herein may result in hazardous radiation exposure.
those specified herein may result in hazardous radiation exposure.
Contact your Lucent Technologies representative for more information.