Panasonic WV-NS324 사용자 설명서

다운로드
페이지 64
-47-
Note:
Input an external alarm signal of more than
100 ms.
3. Alarm Preset
Select the item by pressing the [o] button, and
click the [SET] button.
1POSI:
Camera performs according to Preset posi-
tion 1 when there is input at ALARM IN 1.
2POSI:
Camera performs according to Preset posi-
tion 2 when there is input at ALARM IN 2.
OFF:
No alarm preset used. Set Preset position 1
and 2 in advance when using this function.
The default setting is OFF.
4. E-mail Notice Setup
E-mail Notice:
In ON position, an e-mail is sent
when alarm arises. The default is OFF.
E-mail Server Address:
Input the Mail Server
Address in not more than 128 numbers or
small letters of one byte. When using DNS,
input "host name. Domain name".
Sender E-mail Address:
Input the Sender E-mail
Address. The default is NW_Camera.
It is named "NW_Camera@(IP address of cam-
era)" when input without the @ mark.
• Select ON or OFF for Attach Image.
ON:
Attaches the alarmed picture to the e-
mail.
OFF:
No picture attached. The default setting
is OFF.
• Click the [SET & REBOOT] button.
• Enter up to 4 destination e-mail addresses,
and click the [SET] button. 
• Click the [DEL (delete)] button after selecting
an unwanted e-mail address to delete it.
Notes:
• The e-mail address of the sender is one and
the same as that of the administrator.
• Sending mails is not possible in an environ-
ment that requires authentication for SMPTE or
POP3.
5. Recording Setup
The image fields before and after an alarm input
are stored in the memories of the cameras.
• Set the number of image frames for pre
recording (0 - 20) and post recording (1 - 20).
• Set the recording rate (fps: frame per second).
Pre-recording rates:
1/10, 1/5, 1/3, 1/2, 1, 2,
3.3, 5 ..... The default setting is 1.
Post-recording rates:
1/10, 1/5, 1/3, 1/2, 1, 2,
3.3, 5, 10 ..... The default setting is 1.
• Click the [SET & REBOOT] button.
6. Panasonic Protocol Setup
• Select ON or OFF.
ON:
Sends alarm notice mails to the cus-
tomized destinations.
OFF:
Does not send.
• Enter the destination port. The port number
is exclusively assigned to this function, and
any other usage is not allowed.
• Enter a number of retries from 1 to 25.
• Click the [SET] button.
• Enter a maximum of 8 destination IP
addresses, and click the [SET] button.
• Click the [DEL (delete)] button after select-
ing an unwanted destination to cancel it.
Destination IP Address
Input the Panasonic Protocol Destination IP
Address, and click the [SET] button.
7. External Terminal Output Setup
Alarm output is supplied from the Alarm OUT con-
nector when Terminal 1, Terminal 2 or VMD is in
use.
• Select a signal type : 
Pulse:
Holds active status during the specified
time width.
Latch:
Holds active status until reset manually.
• Enter the pulse width (necessary number x
100 ms) if you selected Pulse. A number from
1 to 100 is applicable.
• Click the [SET & REBOOT] button.
8. External Alarm Reset
• Click the [Alarm Reset] button to cancel the
activated alarm.
Note:
Wait around 5 seconds or more when exe-
cuting [SET&REBOOT] button.
FTP Client Setup
Image files can be transferred to the FTP server within
the scheduled time zone.