system.session.sending_count=2&200 OK 
system.session.sending_max=5&200 OK 
system.session.sending(01).bitrate=326k&200 OK 
system.session.sending(01).to.ip=10.0.0.100&200 OK 
system.session.sending(01).to.port=1536&200 OK 
system.session.sending(01).to.protocol=tcp_passive&200 OK 
system.session.sending(01).to.session=http&200 OK 
system.session.sending(01).from.encode=jpeg&200 OK 
system.session.sending(01).from.framerate=1&200 OK 
system.session.sending(01).from.framesize=vga&200 OK 
 
In case of H.264, system.session.sending(01).from.encode=h264baseline or h264high is returned. In case of 
multicast, system.session.sending(01).to.ip becomes multicast IP address. 
Interpretation  Acquire the sending status of the camera. Starting and stopping stream can be occurred in 
random order, so it can happen that sending(01) is vacant though sending(02) has information. 
Allowed users  admin, operator, user 
 
Getting Log 
Format  /api/param?system.log 
Response  Return the following information. These information will be initialized upon turning off the power of the 
camera.   
       Number of seconds after startup, Alarm input, Motion detect, Error 
Response examples  
system.log=&200 OK 
system alive time: 2142sec <----- No. of seconds after startup 
Dec 19 14:35:32 vn-h37 user.info evman: Motion Detect    
<----- Motion detect  
Dec 19 14:36:03 vn-h37 user.info evman: Alarm Detect (m1)  
 <----- Alarm input 1ch (make) 
Dec 19 14:36:04 vn-h37 user.info evman: Alarm Detect (b2)  
<----- Alarm input 2ch (break) 
Dec 19 14:35:18 vn-h37 user.info evman: Motion Detect      
<----- Motion detect 
Interpretation  Acquire the the camera log. Maximum size is 10KB. 
Allowed user  admin 
 
Getting Model Name 
Format  /api/param?system.model 
Example of Response  system.model=VN-H37&200 OK 
Interpretation  Acquire the model name.