VIVOTEK IP2112 사용자 설명서

다운로드
페이지 69
 
 
 
                                                                         
 
37
 
 
 
 
 
Command Script for Complex Applications 
Besides the application wizard, Network Camera provides a more professional command 
script for advanced applications. The command script will be executed exclusively with 
the settings in Application page of system configuration except for the weekly schedule. 
To build the advanced application, follow the steps below. 
1. Use any text editor to edit the appropriate command script according to the command 
format. The script size cannot exceed 500 bytes.   
2. Save the script as a file named “SCRIPT.TXT”. 
3. Use FTP with administrator’s privilege to upload the script file. 
4. Enter the Application page in system configuration to define the time period in weekly 
schedule. If it is supposed to run any time, keep the original settings but check the 
option “All the time except for the above schedule”. 
5. Check the option “Enable the external script file to exclude the following settings” to 
activate the command script. 
     
Command format 
[Event][“Operator”Event]……=[Action][+Action]……; 
Event 
[“Digital Input Number””Digital Input State”] 
[“M” “Channel Number…”] 
[
Channel Number””Video Input State”]   
Operator 
“+”:  (OR) 
“*”: 
  (AND) 
Action 
[(“Delay Time”)“Digital Output Number””Digital Output State”] 
[“V”“Channel Number”“P”“Preset Location Number”] 
[“W”{“IP”:“Port”}{“Message”}] 
[“U”“Method”] 
[“S”“Channel Number…”] 
[“N”{“filename”}]; 
 
 
Parameter explanation 
Item between brackets means optional but at least one item should exist. 
“Digital input number”:    always 1