JVC LST0728-001C 사용자 설명서

다운로드
페이지 168
97
Input/Output Terminal on Rear Panel
● The audio input acts as a network device in the VR-N1600U/E 
system, and the device name assigned to it is 
ANVRB. The input/
output terminals on the rear panel have been assigned to the 
ANVRB device by default. (VR-N1600U/E)
● In VR-N900U, analog input circuitry is considered as a network 
encoder (IP video server), and the device name assigned to it is 
AN900B. The input/output terminals on the rear panel have been 
assigned to the 
AN900B device by default. (VR-N900U)
䡵 Rear Panel Input Terminals
䡵 Output Terminals
Note :                                                                                               
● Although the duration of output for the rear panel output 
terminals is indicated as0 seconds, it is infinitely output.
● Output events of the rear output terminals cannot be deleted.
● All terminal inputs are treated as alerts, but there can only be 
association (sequence) between one terminal with recording 
                                                                                                    
start.
Specifying a VMD Event
Select the camera for specifying the VMD event 
from the [Defined events] list on the [I/O Setup] 
screen
Click the [Add VMD Event(Motion Detection)] 
button
If a multi-camera device is selected, such as a network encoder (IP 
video server), a dialog for you to select the required camera will 
appear.
Note :                                                                                               
● The [Add VMD Event(Motion Detection)] button is disabled if 
                                                                                                    
there is no VMD event available for the network camera.
Specifying Timer Events
You can add a timer event to an added event.
A timer event is defined with respect to an input event and is 
triggered by that event. Timer events are triggered when the 
specified time interval has lapsed after occurrence of the input 
event at the preset destination.
Select the event for adding a timer event from 
the [Defined events] list on the [I/O Setup] 
screen
(An example of adding a timer event to the input 
event)
Click the [Add new event...] button
● The [New Timer] screen appears.
Specify the timer interval and timer event name.
Rear Panel Input 
Terminal Name
Name of Input Event
Event Description
ALARM IN 1 to 8
(VR-N1600U/E)
ALARM IN 1 to 4
(VR-N900U)
Alarm IN 1 to 8 Falling
(VR-N1600U/E)
Alarm IN 1 to 4 Falling
(VR-N900U)
Event during 
detection of Make 
signal input
Alarm IN 1 to 8 Rising
(VR-N1600U/E)
Alarm IN 1 to 4 Rising
(VR-N900U)
Even during 
detection of Break 
signal input
Rear Panel Output 
Terminal Name
Name of Output Event
Output Action
OPTION OUT1,2
Set output Option Out 1,2 
high
Outputs the Make 
status
Set output Option Out 1,2 
low
Outputs the 
Break status
Item
Description
A
Timer 
event is 
started 
by:
Displays the event or event button name for 
which a timer event is added. (This is a read-
only field.)
B
Timer 
event 
name
For specifying a name for the timer event.
C
Timer 
event 
occurs 
after:
For specifying the time interval from the 
occurrence of the event or clicking of the event 
button until the timer event is triggered. Specify 
the time interval in seconds or minutes.
[I/O Setup] Screen
A
B
C
[New Timer] Screen