134
Applications
When SNMP is enabled, the status of this unit can be 
monitored from the SNMP manager of the surveillance 
computer. The MIB extension information (JVCNVRMIB.txt) 
must be registered to the SNMP manager. 
Insert a commercially available flash memory 
device into the serial terminal
Select [Unit Setting 2] from the main menu 
[Main Menu List] Screen
Select the [Enable of SNMP] check box in the 
[SNMP setting] section
● To use TRAP, select the [Enable of TRAP] check box in 
the [SNMP setting] section. 
(A Page 135) for the TRAP notifications supported by 
this unit. 
Enter the IP address of the surveillance 
computer in the [SNMP manager’s address] field
Specify the SNMP community name
Example) kanshi1
Note :                                                                                               
● Up to 32 alphanumeric characters can be used for the 
community name. 
● TRAP signals may be missed on the receiving end 
depending on the communication specifications. Operate 
with judgement based on polling primarily and make use 
                                                                                                    
of TRAP only secondarily.
Press [Copy extension MIB onto the flash 
memory] in the [SNMP setting] section
● The MIB extension information is copied to a flash 
memory device. 
[Unit Setting 2] Screen
Register the MIB extension information to the 
SNMP manager of the surveillance computer
● To register the MIB extension information to the 
surveillance computer, refer to the instruction manual 
of the SNMP manager. 
Specify the surveillance (polling) settings for the 
SNMP manager of the surveillance computer
● For details on how to set, refer to the instruction 
manual of the SNMP manager. 
(A Page 135) for the list of status that can be obtained 
from this unit. 
Setting SNMP
2
3
4
5
6