Selecting the Service Pack
The VG4 AutoDome service packs are cumulative. Before you begin a firmware update, check 
the version of the System Controller Main (SC) firmware currently installed in the AutoDome. 
The SC Main firmware version determines the service pack with which you must start. To 
determine the SC Main firmware version:
1.
Issue the ON-66-ENTER command on the keyboard. 
The AutoDome displays the current firmware levels for the AutoDome files. The SC Main 
firmware level is enclosed in the box in the illustration below.
Figure 2.1
Display Software Version Menu
2.
Compare the SC Main firmware level with the following table:
Note: This table contains the latest information as of Service Pack 1.05.01. For 
subsequent service packs, refer to the table in the service pack release notes.
3.
Download the appropriate service packs from www.boschsecurity.com and install each 
sequentially.
Refer to Section 3.2 VG4 Series Firmware Version Identification, on page 31, for more 
information.
2.3
Hardware Connections
This section provides a brief description of the devices necessary to connect a PC (with the 
CTFID software installed) to a VG4 AutoDome. Refer to the AutoDome Modular Camera System 
Installation Manual and to the CTFID User’s Manual for detailed connection information.
System Controller Main
Start with Service Pack Release Date
1.00.00.02 to 1.04.00.02
1.01
July 12, 2007
1.05.00.02
1.02
October 2, 2007
1.06.00.04
1.03
November 19, 2007
1.07.00.01
1.04
January 11, 2008
1.08.00.02
1.05.01
September, 16 2008
Bosch Security Sys. AutoDome(r)
500 Series
Day/Night 26X
FastAddress:  Not Set
1.06.00.04 /1.05.00.02
2.00.00.00