3M ET 350 사용자 설명서

다운로드
페이지 106
3M Dynapro ET 350 Monitor User’s Installation Guide
18
Figure 6: Connecting AC power cable wires to connectors
5.
Using a 1/8-inch flathead screwdriver, turn the terminal block’s screw 
clockwise until the neutral cable wire is firmly attached to the ET 350 
monitor. 
6.
Repeat (3) and (4) for the ground and line cable wires.
7.
Tighten the screws on the terminal block to a torque of 10 inch-
pounds.
8.
Fasten a cable tie around the three wires at about one inch from the 
terminal block (Figure 7).
Figure 7: Terminal connection: ET 350R and ET 350L3 monitors
9.
Slide the insulator up the power cable, positioning it so that one end 
of the insulator is flush with the terminal connector and the other end 
overlaps the power cable jacket by at least one inch.
10.
To prevent the insulator from moving up or down the cable, secure 
the insulator to the chassis of the ET 350 monitor using a cable tie or 
other equivalent securing device. 
- N/L2 NEUTRAL
-          GROUND
- L/L1 LINE
32531
Cable tie
Cable tie
(inside insulator)
Insulator
Terminal block