RedMax EBZ5150 사용자 설명서

다운로드
페이지 18
US-16
EBZ5150/RH
BEFORE STORING THE BLOWER:
1. Drain a fuel tank and push the primer
bulb until it becomes empty of fuel.
2 .Remove the spark plug and drop a
spoonful of 2-cycle oil into the cylider.
Crank the engine several time and
install the spark plug.
3. Store unit in a dry, dust free place, out
of the reach of children. 
10. Storage
11. Disposal
• When disposing your machine, fuel or
oil for the machine, be sure to allow
your local regulations.
Case 1. Starting failure 
CHECK
PROBABLE CAUSES
ACTION
fuel tank
incorrect fuel
drain it and with correct fuel
fuel filter
fuel filter is clogged
clean
carburetor adjustment screw
out of normal range
adjust to normal range
sparking (no spark)
spark plug is fouled/wet
clean/dry
plug gap is incorrect
correct (GAP: 0.6 – 0.7 mm)
spark plug
disconnected
retighten
Case 2. Engine starts but does not keep running/Hard re-starting.
CHECK
PROBABLE CAUSES
ACTION
fuel tank
incorrect fuel or staled fuel
drain it and with correct fuel
carburetor adjustment screw
out of normal range
adjust to normal range
muffler,cylinder (exhaust port)
carbon is built-up
wipe away
air cleaner
clogged with dust
wash
cylinder fin, fan cover
clogged with dust
clean
When your unit seems to need further service, please consult with our service shop in your area. 
12. Troubleshooting guide