Cal Flame A526 사용자 설명서

다운로드
페이지 32
LTR20091024, Rev. A
9
Spa Model
GFCI Required Wires Required
Portable Spas
All 240V spas (except 
6300 control boxes re-
quiring high amperage 
- see below)
One 50 amp GFCI
Four #8 AWG copper 
wires
Spas with the 6300 
control box (when high 
amperage is selected on 
circuit board)
SEE CONFIGURATION 
INSTRUCTIONS ON 
NEXT PAGE.
One 60 amp GFCI
Four #8 AWG copper 
wires
Ul
timate Fi
tness Spas
F2400 spa with one 
5.5 kW heater
One 50 amp GFCI
Four #8 AWG copper 
wires
F2400  and  FP2500  spas 
with two 5.5 kW heaters
Service 1: One 60 
amp GFCI
Service 2: One 30 
amp GFCI
Service 1: Four #8 
AWG copper wires
Service 2: Three #8 
AWG copper wires
FP4700 spa
Service 1 (swim 
side): One 60 amp 
GFCI
Service 1: Four #8 
AWG copper wires
Service 2 (swim 
side): One 30 amp 
GFCI
Service 2: Three #8 
AWG copper wires
Service 3 (spa side): 
One 40 amp GFCI
Service 3: Four #8 
AWG copper wires
In-Gr
ound Spas
Designer in-ground spas 
with one 5.5 kW heater
One 50 amp GFCI
Four #8 AWG copper 
wires
Designer in-ground spas 
with two 5.5 kW heaters
Service 1: One 50 
amp GFCI
Service 2: One 30 
amp GFCI
Service 1: Four #8 
AWG copper wires
Service 2: Three #8 
AWG copper wires
DIJ407 spa
Service 1: One 60 
amp GFCI
Service 2: One 30 
amp GFCI
Service 1: Four #8 
AWG copper wires
Service 2: Three #8 
AWG copper wires