Nilfisk Alto 03KLU 사용자 설명서

다운로드
페이지 15
16
  12.0  Diagnosis of faults and repair 
EN
Fault Cause  Repair
The motor fails to start  
Oil supply not connected 
Connect the oil hose
 
Oil supply closed 
Open the valve
 
No oil pressure 
Start the hydraulic pump
 
The pump is frozen 
Let the pump thaw
Working pressure too high   Nozzle partly blocked 
Clean the nozzle
Working pressure too low  
Valve for regulation of water  
Open fully the valve for regulation
 
capacity is not adjusted to max.   of water. Turn in the direction
 
pressure 
indicated by the arrow
 
Regulating valve open 
Close the regulating valve
Irregular working pressure   Air in the pump 
Repeat the venting procedure
During self-priming 
Suction height too high or water   Read the paragraph conc. self-
 
too hot 
priming p. 6
 
Filter blocked 
Clean the fi lter. See p. 11
During direct water 
Insuffi cient water supply from   
Change to a water supply with
connection 
the water works 
greater output. If this is not
 
 
possible; turn the valve for regulation of 
 
 
the water capacity in the opposite 
 
 
direction of that indicated by the 
 
 
arrow, until the machine works smooth ly.
No working pressure  
Nozzle blocked 
Clean the nozzle
 
No water 
Check the water connection
 
High pressure hose/lance frozen  Allow the high pressure hose/lance
  
to 
thaw
 
By-pass valve frozen 
Allow the machine to thaw
Should faults occur other than those mentioned above, please contact the nearest Nilfi sk-ALTO service 
or gan i za tion.