TROUBLE SHOOTING GUIDE
PROBLEM
Engine will 
not start (see 
Engine Manual 
for further 
engine  
troubleshooting)
No or low 
pressure 
(initial use)
CAUSE
CORRECTION
No fuel.
Add Fuel.
Pressure builds up after two pulls 
on the recoil starter or after initial 
use.
Squeeze gun trigger to relieve 
pressure.
Spark plug wire not attached.
Attach spark plug wire.
Spray wand not in high pressure.
See How to Use Spray Wand 
instructions in the Operation 
Section.
Low water supply.
Water supply must be at least  5 
GPM @ 20 PSI.
Leak at high pressure hose fitting.
Repair leak. Apply sealant tape 
if necessary.
Nozzle obstructed.
See Nozzle Cleaning instructions 
in the Maintenance section.
Water filter screen clogged.
Remove and clean filter.
Air in hose.
Turn off the engine, then the 
water source. Disconnect the 
water source from the pump inlet 
and turn the water source on 
to remove all air from the hose. 
When there is a steady stream 
of water present, turn water 
source off. Re-connect water 
source to pump inlet and turn on 
water source. Squeeze trigger to 
remove remaining air
High pressure hose is too long.
Use high pressure hose under 
100 feet.
Low oil
Add required amount of oil.
Choke lever in the "Choke" 
position on a "hot" engine or an 
engine that has been exposed to 
thermal heat for a long period of 
time.
Move choke to the "No Choke" 
position.
Choke lever in the "Choke" position. Move choke to the "No Choke" 
position.
Choke lever in the "No Choke" 
position.
Move choke to the "Choke" 
position.
Engine ON/OFF switch in OFF  
position.
Place engine ON/OFF switch in 
ON position.
Fuel valve closed
Move the fuel valve lever to the 
"Open" position.