DUAL LANCE ASSEMBLY WITH ADJUSTABLE PRESSURE:
This unit features a Dual Lance Assembly with adjustable pressure which 
allows the user to select a high or low pressure "fan" spray.  Simply rotate 
the  adjustable  grip  on  the  dual  lance  to  achieve  the  desired  pressure 
selection.
1.  Selection of high pressure can be achieved by turning the adjustable grip 
on the Dual Lance assembly counterclockwise as shown in the figure 
below.
2.  Selection of low pressure detergent application can be achieved by turning 
the adjustable grip on the Dual Lance clockwise as shown in the figure 
below.  Once the pressure is low enough, the detergent injector on the 
pressure washer will draw detergent into the system.  A water/detergent 
mixture exits from both the spray nozzle and detergent nozzle.
DUAL LANCE CONNECTION:
1.  Be certain the trigger gun is locked in the "OFF" position.
2.  Connect the dual lance assembly to the trigger gun assembly at this time. 
Be certain the connection is securely tightened.
INSTALLATION & PREPARATION
WARNING
RISK  OF  INJECTION  CAUSING 
SEVERE INJURY!
-THE  TRIGGER  GUN  SHOULD 
ALWAYS BE LOCKED IN THE OFF 
POSITION WHEN NOT IN USE!
-NEVER  LOOK  DIRECTLY  AT 
THE  NOZZLE  UNLESS  IT  IS 
DISCONNECTED  FROM  THE 
TRIGGER  GUN/DUAL  LANCE 
ASSEMBLY!
 
WATER SUPPLY:
1.  Select  a  water  supply  hose  which  is  a  quality  grade  of  garden  hose 
measuring at least 3/4" ID and no longer than 50 feet.
2  Check  the  water  inlet  strainer  to  ensure  it  is  clean  and  free  of  any 
obstructions.  As a strainer becomes obstructed, it restricts proper flow of 
water to the pump.  This can result in cavitations which will prematurely 
cause failure of pump packings. 
a.  Unscrew the strainer cap from the unit.  
b.  Remove the strainer screen and clean, or replace.
3.  Connect one end of the water supply hose to the water inlet of the unit.  
Connect the other end of the hose to your pressurized water supply.  
NOTE:  When connecting the water inlet to the water supply mains, local 
regulations  of  your  water  company  must  be  observed.    In  some 
areas, the unit must not be connected directly to the public drinking 
water supply.  This is to ensure there is no feedback of detergents 
into the water supply.  (Direct connection is permitted if a backflow 
preventer is installed.  Check with local authorities for approval.)
NOTE:  If the mineral content of the water in your area is extremely high, the 
use of a water softener is recommended to prevent the possibility of 
excessive scale buildup inside the heat exchanger coil.
4.  Follow the incoming water requirements listed below:
a.  Water pressure must be a minimum of 20 pounds per square inch 
(PSI) and a maximum of 125 PSI.  (A typical outdoor faucet will 
generally supply this PSI if turned completely "ON".)
b.  Incoming GPM must be  approximately one gallon more than the 
outgoing GPM stated on the pressure washer nameplate.  (You can 
check GPM by timing how long it takes to fill a 5 gallon container.)
c.  Incoming water temperature must not exceed 125°F.  Excessive pump 
damage may result if the water temperature exceeds this acceptable 
level.
5.  Never allow the unit to operate without the incoming water line attached 
and the water supply is completely turned on.
WATER INLET STRAINER